Blast Design for Controlling Some of Environmental Nuisances during Deep Hole Blasting in Surface Overburden Benches - Juniper publishers
Journal of Insights in Mining Science & Technology
Abstract
The
present study suggesting a safe methodology to control blast induced ground
vibration and air overpressure within the safe limits specifying the safe
permissible explosive charge per delay and per round along with the blast
design parameters which should be used while blasting mainly to protect
vulnerable structures in the vicinity. Keeping in view the above-mentioned
requirements, 11 rounds of deep hole trial blasts were studied constituting all
together 19 blast events recorded by seismographs. While selecting the blast
monitoring stations all the sensitive points have been covered which mainly
included, dwellings and structures belonging to owner and a few other places
within the mine in order to study the blast induced wave propagation and
attenuation for various scaled distance. Safe charges have been recommended
after regression analysis and suitable blast patterns were recommended for safe
and productive blasting.
Keywords : Ground vibration; Fly rock; Air overpressure; Deep hole; Overburden
benches
Introduction
In blasting operation, the local geological conditions must be
considered first. Rock competency and fracture patterns have a significant
impact on the success of a blasting operation [1]. Due to widely varying nature
of rocks, geological structure and explosive materials, blast design
parameters are optimized by field testing but monitoring of blast vibrations
during actual excavation helps to ensure the safety of the concerned structures
as well as to provide necessary data to improve the blasting patterns if required
[2]. Venkatesh [3] concluded that the total charge in a blast influences insignificantly
on the intensity of the ground vibrations for distances between 100m and 3000m.
With the combination of delay detonators and proper blast design, large scale
blasts are possible without any significant increase in the vibration levels.
The author
Wiss & Linehan [4] made studies to evaluate the influence of 14 blast
variables considered to influence the amplitude of ground vibrations. Monjezi
et al. [5] observed from the sensitivity analysis that distance from the site
of blast, number of holes per delay and maximum charge per delay are the most
influential parameters towards generation of ground vibration in the blasting
operation. The ground vibration characteristics depend on maximum charge per
delay in any one of the delay intervals instead of total charge used in blast
[6]. They found that the charge weight per delay and length of delay to have
the most significant influence on ground vibrations. Charge weight per delay is
a very important parameter which controls the intensity of ground vibrations.
The intensity of vibrations increases as the quantity of charge detonated per
delay increases. The selection of a suitable delay interval is extremely
important in multi-row blasts. The function of delay detonation is to separate
the pressure front into bundles of energy delivered to rock mass to make the
events occur in series, independent of breaking. Proper burden relief should be
provided to each row for effective movement of the burden rock [7]. If the
delay between rows is not enough, the front row burden cannot move forward to
enough distance to provide free face to the next subsequent row to move out
[8,9]. This adds to more confinement of charges in subsequent rows leading to
increased ground vibrations and fly rock. It was found that the ground vibration
levels could be reduced effectively by arranging delays between rows in such a
manner to separate the wave fronts emanating from corresponding charges
avoiding the superimposition of waves [10]. Due to higher scattering in Nonel
initiation system, it is found that the percentage of seismic energy
dissipation during blasting using Nonel initiation system is higher in
comparison to blasting using an electronic initiation system. The overlapping
of holes leads to improper utilization of explosive energy during blasting with
Nonel initiation system than an electronic initiation system [11]. Data
evaluation is not solely based on peak particle velocities, as it is for
conventional methods. Seismic waveforms, their frequency content, and their
time-duration are also considered [12].
The probability study
made by Dowding [13] revealed that no cosmetic or threshold cracking takes
place below a particle velocity of 12mm/s. The data considered by him for the
study included the low frequencies of below 4 Hz collected by Dvorak [14]. Residential
structures typically resonate at frequencies in the range of 3Hz to 8Hz
indicating a problem. However, the above study indicated no danger even upto
12mm/s PPV with such low frequencies. To substantiate this Siskind et al. [15]
conducted studies and observed no blast-induced cracking upto 19mm/s PPV. The
probabilistic data provided above may not be valid in specific cases as total
time history of vibration event is more important for response spectrum of the
structure. The damage that results from vibration will depend on the nature of
source, transmission characteristics of the intervening medium/strata, inherent
strength of the subject structure, height and rigidity of the structure and
foundation design etc. Damage caused by ground vibration is dependent on the
amplitude of the ground velocity and on the frequency of the ground motion. All
the vibration standards till date are based on the resultant peak particle
velocity of ground vibration because this is accepted as the best criterion for
assessing levels of vibration damage. The recent trend is to refer to the
frequency of the ground motion also. Low frequency waves cause more damage to
structure particularly in case of multi-storied buildings. Different countries
adopt different standards of safe limits of vibration in terms of peak particle
velocity (PPV) for various types of structures. In India DGMS suggested
standards of blast vibrations vide their circular No.7 of [16] are being
implemented. Accordingly, the permissible peak particle velocity (PPV) at the
foundation level of structures in mining area is detailed in Table 1.
Objective
The objective of the study was to suggest the maximum explodable charge
per delay (MCPD) and per round for limiting the Peak Particle Velocity (PPV) of
ground vibration within permissible limits for NONEL system of blasting with
emulsion explosives considering the existing surface structures in the vicinity
of the mine.
Case
Description
To meet the stated objectives, a field study was conducted on
sandstone overburden formation of an opencast coal mine of BCCL, a subsidiary
of Coal India Ltd. (CIL). The mine is being worked by mechanized drilling and
deep hole blasting method. Crawler mounted DTH pneumatic drill of 150mm
diameter is being used to drill blast holes. The holes are made near vertical.
Staggered pattern of drilling is to be followed for optimum distribution of
explosive energy. However, pattern of drilling was found to be not very
consistent on a few occasions leading to improper burden relief affecting
fragmentation and causing boulder generation. Lack of proper bench face is
also seen on a couple of occasions due to new opening of benches. The strata
are also found to be disturbed due the presence of old depillared/caved
workings. Numerous free faces caused low vibrations levels and improper
fragmentation due to loss of explosive energy. This needs a special attention
of mine management for realizing the fruits of good blast design. All the 11
trial blasts utilized Nonel system of initiation with trunk line delays of
17/25ms between the holes in a row and 25/42ms between the rows. Down the hole
initiation systems of 250/300ms (of varying length depending on hole depth)
were used with deck charging. Details of tie-ins and initiation arrangement
are given in Figure 1 and according to figure the MCPD of suggested firing
pattern having quantity of individual blast hole as compare to another pattern.
Depth of
blast holes, in various round of blasts, in general, varied from 6 to 7 m. The
effective burden varied from 2.5 to 3.0m and spacing varied from 3.0 to 3.5m.
The charge per round varied from 400kg to 2115kg and the maximum charge per
delay varied from 30kg to 130kg. Blasting was carried out using cartridge explosives
and site mixed emulsions (SME) explosives and cartridge booster Explosives. It
was found that powder factor varied between 1.0-2.2m3/kg of explosive depending on
formation (compact /cracked), type of initiation sequence and other blast
design variations.
Methodology
To meet the above
stated objective field reconnaissance was done to identify the different
formations and fragile locations such as benches facing human habitat and
nearby the villages. During the study 11 trial blasts with non-electric delay
(NONEL) were conducted and ground vibration and air overpressure were monitored
(Figure 2) with the help of Minimate/ Minimate plus seismographs. A total of 19
events were recorded by these seismographs at various blast monitoring
stations nearest to the blast site as shown in Table 2 & 3.
Analysis and Discussions
The analysis of ground vibration records as presented in Table 4 reveals
that the dominant frequencies of the ground vibration in the mine varied from 3.5
to 32.5Hz. It may be noted that most of the frequencies were ranging between
8-25Hz (74 %). Considering the surface structures (brick houses on cement
belonging to owner) as the critical structure to be protected, the maximum
allowable Peak Particle Velocity (PPV) is fixed at 15mm/s based on the trial
blasts and the ground vibration monitoring near structures during blasting
(refer to Table 1 on DGMS guidelines).
Ground
Vibration Predictor
Applying the method of least square regression analysis, an
empirical equation is established relating resultant peak particle velocity, V
(mm/sec) of the ground, the distance of blasting site from the point of
monitoring, R (m) and the maximum charge per delay, W (kg) (Figure 3). The
derived empirical ground vibration predictor equation for the mine with
Non-electric (NONEL) initiation system is given below (Eq. 1):
1.44 891*( ) R
V W − = (at 95% confidence interval) (Eq.1)
Coefficient of determination (R2) = 0.63
Equation 2 depicts the relation among resultant peak particle
velocity, V (mm/sec) of the ground, the distance of blasting site from the
point of monitoring, R (m) and the total charge per round, TW (kg) (Figure 4).
1.62 200*( ) R
V TW − = (at 95% confidence interval) (Eq.2)
Coefficient of determination (R2) = 0.65
The scaled distance
and peak particle velocity values are plotted on a log-log scale.
Statistically, the above equations have reasonable index of determination and
therefore can be accepted for prediction of ground vibration and estimation of
safe maximum charge per delay and per round for various distances of structures
from the blasting sites. The suggested maximum charge per delay using Nonel
initiating systems (TLD & DTH) for the safety of surface structures is
given in Table 5.
Air
Overpressure Monitoring
During trial blasts air overpressure (air blast) was also monitored
and the details of measurements are given in Table 3 & 4. The values
obtained were analyzed for a propagation equation and the same has been shown
in Figure 5. All the observations were well within safe permissible limits.
0.07 3 158*( ) R
AOP W − = (Eq.3)
Coefficient of
determination (R2) = 0.71
A
good index of determination has been obtained by eliminating judiciously the
offsets which are because of wind speed, RL difference, lack of bench face etc.
Conclusion
This
paper presents the scientific investigations on the assessment of ground
vibration and air overpressure while blasting in the mine. During the
investigation period 11 rounds of blasts comprising a total of 19 events were
recorded. Based on the analysis of data following conclusions may be drawn:
a) The site-specific
empirical equation relating vibration, distance and maximum explosive quantity
per delay for the overburden rock is
1.44 891*( ) R V W − =
Coefficient of
determination (R2) = 0.63
The dominant
frequencies of ground vibration in the 11 rounds of blasts recorded varied from
3.5Hz to 32.5Hz. However, most events (74%) recorded dominant frequency with
more than 8Hz.
b) Assuming a safe level
of ground vibration as 15mm/sec for safety of surface structures (kuchha brick
houses with ce ment) near the mine belonging to owner and 20mm/sec for concrete
structure not belonging to owner, the maximum permissible charge per delay is
calculated using site specific empirical equations for various distances of
surface structures from the blast site and the results are given in Table 5.
c) The
AOP is in the safe limit and maximum percentage of noise is below 120db which
causes minor harm to the habitats.
Acknowledgement
The authors express
their gratitude towards the staff and management of BCCL, a subsidiary of Coal
India Ltd. for granting permission to conduct the study.
To Know More About Insights in Mining Science